Supply and Interface Module VI156

The VI156 supply and interface module enables the direct connection of non-intrinsically safe sensors / actuators or signals to the DC155 dosing controller or the PR130 process controller.

Features
  • For use in Ex-zones 1 & 2, installation directly in the Ex-area
  • Enables intrinsically safe voltage and signal supply
  • No additional terminal boxes required, as the housing complies with protection type "Increased safetyEx e
  • Includes input isolating stages, output isolating amplifiers, an open collector output and an Ex i power supply unit
  • Optional: Interface conversion (TTY, RS232)
  • Optional: Extended Ex e terminal compartment (18 terminals)
Supply interface VI156

.

.

.

Mains*:

230V AC ...................................
120V AC ...................................
24V DC .....................................

 

.0
.2
.6

 

 

Ex TTY/RS232 serial interfaces:

without .................................................
with .......................................................

 

.0
.1

 

Extended Ex e terminal compartment (18 terminals):

without .................................................
with .......................................................

 

.0
.1

* - other voltages on request

Vielen Dank für Ihr Feedback!

Vielen Dank für Ihr Feedback!